Electromagnetic induction aluminum foil sealing machine use matters needing attention:
1, do not apply metal container and metal cover, but not on the metalsurface by pressing the start button, otherwise it will damage the machine.
2, through the power of the aviation plug is inserted before induction, and tighten the screws.
3, the use of single phase three wire power line, in order to make the operator safety, be sure to use the single-phase three wire power socket,workplace surface must be dry, in order to maintain the insulation.
4, with over temperature automatic protection function, the temperaturewhen the machine, machine buzzer ringing "abnormal protection (PRO.MD.)" the yellow indicator light, you should turn off the power switch, the standby cooling buzzer stops, and then continue to work.
5, work in process should always touch sensing head surface, check whether the overheating, such as the discovery of hot should stop heating,after cooling to work (cooling can not power off), "ready (WARM UP)" the green indicator light does not shine, do not press the start button, to prevent false triggering. The machine after the end of the work, please turn off the power switch on the panel.
6, equipped with a fuse is 5A, not available than 5A insurance instead of.
7, there are high-pressure, floor charged, unauthorized repair, in order to avoid the electric shock of the people.
8, before using, as found in a bare wires should stop using this machine,the repair before use.
9, transportation, storage, can not hit, when in use, moisture stress.
10, product check and acceptance, under normal transport, packaging intact circumstances, such as found in contact to the company timely parts and products with the packing list does not comply.
11, according to the instructions for use, operation should be clear, such as found in product manufacturing quality problems, that within the time limit prescribed in the company, the equipment warranty for six months and is responsible for repair.
(Note: the unit is provided with the current limiting protection, when thesealing foil area is too large, or is too close to the induction coil, automaticshutdown output, built-in buzzer ringing, panel "abnormal protection (PRO.MD.)" the yellow indicator light, until the recovery so far.)